Space Works · Developers
Adapter API reference
Base path: /api/v1/device/adapter/v1/. All routes are signed (authentication), JSON, and
validated against the schemas in schemas/ (the same dicts the server uses). Errors are
{"detail": "...", "code": "..."}; see errors.md.
POST hello
{ "protocol_version": 1, "adapter_kind": "fdm_printer", "vendor": "acme", "software_version": "1.4.2",
"capabilities": [{ "name": "status", "version": 1 }, { "name": "control", "version": 1 }] }
Response 200:
{ "device_id": "...", "protocol_version": 1, "server_time": 1760000000, "config_version": 3, "poll_seconds": 15,
"capabilities": [{ "name": "status", "version": 1 }], "unknown_capabilities": [],
"bindings": [{ "id": "...", "target_type": "machine", "machine_id": 12, "target_id": "",
"external_ref": "printer-a", "capabilities": ["control", "events"] }] }
adapter_kind is one of fdm_printer resin_printer laser cnc generic shelf_pointer label_printer scanner door sensor
kiosk. Unknown capability names are returned in unknown_capabilities, never fatal. config_version rises when
staff bind or unbind a target; re-read GET bindings when it changes.
GET bindings
{ "bindings": [ ...as in hello... ] }
POST status
{ "items": [{ "binding_id": "...", "observed_at": 1760000000, "state": "running", "progress_percent": 40,
"power": "on", "busy": true, "error_codes": ["filament_runout"] }] }
state: idle preparing running paused finished failed error offline maintenance (running = busy/active).
Response: {"results": [{"binding_id": "...", "result": "stored|stale|throttled|unknown_binding"}], "config_version": 3,
"server_time": ...}. A report not newer than the stored one is stale; more than one per binding per 5 s is
throttled. Status is advisory: it never changes Machine.status.
POST events
{ "events": [{ "operation_id": "<uuid>", "binding_id": "<uuid>", "type": "maintenance.fault",
"observed_at": 1760000000, "data": { "code": "hotend_clog", "severity": "fault", "detail": "..." } }] }
Up to 50 per call. Idempotent by operation_id ({"result": "stored|duplicate"}). The type must belong to a
capability the adapter declared (else event_not_declared) and, with a binding_id, to one that binding serves.
Server reactions: maintenance.fault is written to the machine's technical-fault log; safety.area_cleared
records the area-clear confirmation the access decision enforces; the rest are stored for staff.
POST commands/lease and POST commands/{id}/ack
Lease returns {"command": null} or
{ "command": { "command_id": "...", "binding_id": "...", "capability": "control", "command": "pause",
"params": {}, "lease_token": "...", "lease_expires_at": 1760000300 } }
Ack: {"lease_token": "...", "outcome": "succeeded|failed", "result_code": "ok"}. At-least-once: an unacknowledged
lease expires and the command returns to the queue (bounded attempts, a TTL of ten minutes). A re-ack is idempotent. Every lease is audited as devices.adapter_command_leased (binding, command, capability,
command name and attempt; never the token or the params), next to adapter_command_queued (who asked) and
adapter_command_acked.
A command whose capability's child switch went off after it was queued is never leased (it fails with
capability_switched_off). Commands: control (pause resume cancel power), door.access (unlock),
locate.indicate (indicate), locate.calibrate (aim jog), media.snapshot (snapshot), label.print
(print), diagnostics (log_bundle), job.dispatch (cancel_job). Params match schemas/command.*.json.
POST access/authorize (child switch machines.integrations.access)
{ "binding_id": "...", "credential": { "type": "card_qr|nfc|pin", "value": "...", "member_number": "123", "pin": "..." } }
Response 200: {"allowed": true, "decision": "allowed", "reason": "ok", "max_seconds": 14400} or
{"allowed": false, "decision": "denied", "reason": "no_machine_access"}.
Credentials (identification is not authentication):
- nfc: value is the tag id.
- pin: value is the PIN and member_number the number printed on the member card.
- card_qr: value is the member card's desk QR (32 hex characters) and pin the member's PIN. A card QR alone
is refused with pin_required (prompt for the PIN and retry). A public card check link (/verify/c/...) or its
bare token is never accepted: it is printed for anyone to verify a card, so it proves nothing about who holds it.
Every member-level failure (unknown tag, card or member number, no PIN set, wrong PIN, a locked or disabled
credential) answers the same unknown_credential, so a keypad cannot learn who has a PIN. Five wrong PINs in a row
still lock that member's PIN for 15 minutes (silently). Each binding (10) and each space (30) also has a budget of
failed PIN and card-QR attempts per 15 minutes; when it runs out, PIN and card-QR attempts there answer
too_many_attempts for a cooldown that doubles each time it trips within a day (5 minutes up to 24 hours), even
for a correct PIN. NFC is not budgeted. Reasons: access.response.json (unknown_credential pin_required too_many_attempts
member_restricted membership_required waiver_acceptance_required presence_required no_machine_access machine_access_expired
machine_unavailable machine_in_use session_already_live booking_required booked_by_other maintenance_lockout
area_not_clear filter_alert internal_error_fail_closed ...). The decision is the existing session rules (machine; a space manager's machine-access grant; certifications no longer matter) or
active, unrestricted membership (door/space). A denial never changes a running session; any unexpected error is a
denial (internal_error_fail_closed). Every decision is an append-only log row and an audit row.
Bridges that map our reasons onto another system's refusal vocabulary (a Fabman-style bridge, for example) should
map no_machine_access to "member not authorised for this resource" and machine_access_expired to "authorisation
expired"; both are fixed by the space manager's grant, so the bridge shows "ask a space manager", not "get trained".
POST sessions/start and POST sessions/{id}/stop
Start takes the same body as authorize and, when allowed, starts a machine session (source device) through the
machine-session service: {"allowed": true, "session_id": 77, "max_seconds": 14400} (denials as authorize). It needs
machines.sessions on. Stop: {"reason": "member|device|idle", "active_minutes": 20, "idle_minutes": 2} and only for a
session this adapter started; the usage entry and any charge are raised by the session service (charge-tracking ledger).
POST usage (child switch machines.integrations.usage_billing)
An immutable usage record (schemas/usage.log.json), idempotent by operation_id: {"result": "stored|duplicate"}.
Staff routes (/api/v1/admin/, MANAGE_DEVICES, machine scope)
These routes power the console's adapter area. In short: enroll through the device
routes with kind: "adapter"; GET makerspace/{id}/adapters, GET adapters/{id}, POST adapters/{id}/bindings,
DELETE adapter-bindings/{id}, POST adapter-bindings/{id}/commands, GET adapters/{id}/commands|events; poses,
aim, jog, indicate and position for shelf pointers; credentials; camera watch sessions.
Console read-back and log lists
AdapterSummaryalso carriesonline: bool(active, seen at least once, no open offline edge) andoffline_since: datetime|null(null when online; for a never-seen adapteronlineis false andoffline_sincenull). Each summary binding and everyBindingresponse carriesconfig(the binding's OWN overrides,{}if none) andeffective_config({key: {"value": ..., "source": "type"|"binding"}}:type= follows the machine-type profile,binding= overridden). Keys:auto_off_idle_minutes, require_area_clear, max_session_minutes, require_filter_ok(type or binding) andauto_apply_terminal(binding only, audited asdevices.adapter_auto_apply_set).PUT adapter-bindings/{id}/configaccepts all five keys and answers200 {id, config, effective_config}; an unknown key is 400.GET adapters/{id}/access-decisions-> DRF page{count, next, previous, results: [{id, binding|null, member|null (user id only), credential_type, allowed, reason, session_id|null, created_at}]}, newest first (page size 24,?page=). Filters:binding(uuid),allowed(true|false),reason,credential_type,since,until(ISO 8601 oncreated_at).GET adapters/{id}/usage-> DRF page of{id, binding|null, operation_id, session_id|null, started_at, ended_at, active_minutes, idle_minutes, outcome, error_code, consumptions, created_at}; filtersbinding,outcome,since,until.GET adapter-bindings/{id}/jobs(same path as the POST dispatch) -> DRF page of{id, service_request_id, service_request_name, machine_name, state (awaiting|reported|applied|needs_review|cancelled), telemetry_state, progress_percent, telemetry_at, outcome, actual_minutes, percent_complete, failure_reason, reported_at, applied_at, created_at, command_status, command_attempts, command_error}; filterstate. Empty for a non-machine binding.- All three need the
machines.integrationsswitch, MANAGE_DEVICES in the space (machine scope for a binding), are 404 across tenants, and never return credential digests, PINs or member contact details.
Paged lists
Every list marked "DRF page" above, plus admin/adapter-bindings/{id}/artifacts, admin/adapter-bindings/{id}/detections, the
job owner's member/adapter-artifacts/requests/{id} and member/adapter-detections/requests/{id} lists and the shelf-check history (GET admin/makerspace/{id}/shelf-checks), answers the standard DRF
page {count, next, previous, results} (page size 24 unless noted, ?page=), not a bare array. The OpenAPI document
describes each as that envelope (AdapterAccessDecisionPage, AdapterUsageRecordPage, AdapterBindingJobPage,
AdapterArtifactPage, AdapterDetectionPage, MemberAdapterArtifactPage, MemberAdapterDetectionPage,
ShelfCheckPage). The unpaged lists (adapters, poses, credentials, config history, shelf locations) stay plain.
Jobs (job.dispatch, file.fetch)
POST jobs/lease -> {"job": null | {job_id, lease_token, lease_expires_at, binding_id, machine_id, service_request_id, has_files}};
POST jobs/{id}/ack (schemas/job.ack.json); POST jobs/{id}/progress (job.progress.json); POST jobs/{id}/report
(job.report.json, idempotent by operation_id, a different replay is 409; optional profile_consumptions
[{key, quantity, attributes?}] reports measured use by the machine type's consumable-profile key, e.g. filament in
grams, sheet in sheets, thread in 1,000 stitches; see machine consumables); GET jobs/{id}/file ->
{files: [{file_id, name, content_type, size_bytes, kind, url}]} (short-lived signed URLs, only while the job is
acknowledged). Staff: POST admin/adapter-bindings/{id}/jobs {service_request_id}; PUT admin/adapter-bindings/{id}/config
(auto_off_idle_minutes, require_area_clear, max_session_minutes, enforced by the server).
Kiosk (checkout.kiosk, child switch machines.integrations.kiosk)
POST kiosk/sessions, POST kiosk/sessions/{sid}/scan|evidence|issue|return, DELETE kiosk/sessions/{sid}; schemas
kiosk.*.json. The credential follows the same rules as access/authorize (a card QR needs the member's pin).
A denied credential answers 201 with allowed: false and a reason; a member the self-checkout workflow refuses (not a
personal account, no current term, a guest pass that cannot borrow) gets that typed 4xx, and the attempt is still
written to the access log. Every later call without a live session for this device is 404. The evidence call's
size_bytes is at most 10 MiB (schemas/kiosk.evidence.json, the default EVIDENCE_MAX_BYTES, the same ceiling the
presign enforces); a deployment that lowers the cap refuses a larger declared size with 413 artifact_too_large.
Media (media.stream, media.snapshot, child switch machines.integrations.video)
GET|POST media/{watch}/signal (schema media.signal.json; GET takes ?after= and returns ice_servers),
POST media/{watch}/snapshot (media.frame.json), POST media/{watch}/recording (media.recording.json; needs
machines.integrations.recording and a watch opened with record: true). Viewer routes are under member/adapter-watch/.
Media and data
Audio, two-way talk, artifacts, detections, telemetry history, diagnostics, the offline access cache, remote config and signed time are specified in media-and-data.md.
Notifications
Needs attention, material runout, detections, session ending soon (member) and access denied (staff) go through the
notification catalogue (feature devices: adapter_attention, adapter_runout, adapter_detection,
adapter_session_ending, adapter_access_denied). A terminal job report that waits for staff review (every failed
report, and every report while auto_apply_terminal is off) tells staff once per job (adapter_job_review); the member
hears the outcome through the machine-service notices (printing completed / failed) when staff apply it.
Offline/recovered use the device state edges (a status call counts as liveness); maintenance due is the maintenance
schedule's. The full event list is in notifications.
Webhook push (optional)
Staff: PUT admin/adapters/{id}/webhook {url, include_data} (public https only, port 443 or 8443; the secret whsec_...
is returned ONCE, on creation), POST .../webhook/rotate (new secret, shown once; the old one stops verifying), GET .../webhook,
DELETE .../webhook, GET .../webhook/deliveries (the delivery log). A push is a wake-up (command.queued, job.queued,
config.changed, ping; schema webhook.envelope.json), content-free unless include_data adds the capability and command
names; the work is still leased over the signed API. Verify X-SpaceWorks-Signature: t=<unix>,v1=<hex> where v1 is
HMAC-SHA256 of "<t>.<raw body>" with the secret, and reject a t older than five minutes. Failed pushes retry with backoff
(30 s, 2 min, 10 min, 30 min, 1 h; six tries), and the endpoint disables itself after ten consecutive failed attempts
(re-saving it re-enables it). Each attempt claims the delivery under a 60-second lease, sends with a 5-second timeout and
no redirects, then records the result, so the same delivery is never sent twice at once; after a crash the lease
expires and the push is retried, which is why receivers should deduplicate on X-SpaceWorks-Delivery. A space with
adapters switched off sends nothing; its pushes wait and resume when it is switched back on. Each push resolves the host
name once, refuses it if any answer is not a public address, connects to that exact address (TLS still checks the
certificate against the name), reads at most 4 KiB of your reply and gives up after five seconds in total. The delivery
log says only delivered or failed (last_error = delivery_failed, or url_refused when the name stopped resolving to
a public address); it never shows the status code or network error of a failed attempt.
Safety config and type profiles
PUT admin/makerspace/{id}/machine-types/{type}/adapter-profile sets defaults for every adapter binding on machines of that
type (schemas/safety.profile.json: auto_off_idle_minutes, require_area_clear, max_session_minutes,
require_filter_ok). PUT admin/adapter-bindings/{id}/config overrides any key for one binding and is the only place
auto_apply_terminal lives (schemas/safety.config.json): off by default, so every terminal report waits for staff; on, a
clean (completed) report goes straight through the workflow, and a failed one still goes to review. The setting is audited.
The sweep warns the member five minutes before max_session_minutes, then ends the session through the session service
(stop reason max_length) and queues control power off, exactly like idle auto-off. The sweep also runs in a
read-only space (it only powers a machine off or ends a session, which protects people); a paused space runs nothing.
Shelf pointer poses and caps
Poses are validated by kind when saved (schemas/pose.pan_tilt.json, pose.led_segment.json, pose.galvo_xy.json; a pose
with no kind stays free-form, an unknown kind is invalid_pose). A binding's own config may set laser_max_power_pct
(1..100) and max_on_seconds (1..600); the server clamps every indicate and aim to them and clear is never capped.
See hardware/shelf-pointer.md.
Kiosk shelf light
When a kiosk scan finds a tool with a calibrated pose on a bound pointer, the server queues locate.indicate itself; the
scan response only says "indicated": true|false (poses and locations never leave the server).
Not in this release
The usage-billing rate model.
From SpaceWorks/docs/device-adapters/api.md at c447a11, updated 2026-11-16. Suggest a change